Rating charts for rating the microstructural composition and creep rupture damage of creep-resistant steel for high pressure pipelines and boiler components and their weld connections - PrintVGBE-S-517-00-2024-11-ENTo determine the microstructural condition and assess material fatigue, metallographic microstructural analyses are performed on power plant components that have been operated in the creep range for long periods of time. Real microstructural images, Mehr erfahren420,00 €449,40 € Inkl. MwSt.
-
Rating charts for rating the microstructural composition and creep rupture damage of creep-resistant steel for high pressure pipelines and boiler components and their weld connections - ebookVGBE-S-517-00-2024-11-EN-ebookTo determine the microstructural condition and assess material fatigue, metallographic microstructural analyses are performed on power plant components that have been operated in the creep range for long periods of time. Real microstructural images, Mehr erfahren420,00 €449,40 € Inkl. MwSt.
-
Feed Water, Boiler Water and Steam Quality for Power Plants/Industrial Plants - ebookVGBE-S-010-00-2023-08-EN-ebookvgbe energy e.V. hereby presents a revised version of the VGB-Standard VGB-S-010 for "Feed Water, Boiler Water and Steam Quality for Power Plants/Industrial Plants". This revised vgbe-Standard replaces the former edition 2011.This vgbe-Standard is av Mehr erfahren360,00 €385,20 € Inkl. MwSt.
-
Feed Water, Boiler Water and Steam Quality for Power Plants/Industrial Plants - PrintVGBE-S-010-00-2023-08-ENvgbe energy e.V. hereby presents a revised version of the VGB-Standard VGB-S-010 for "Feed Water, Boiler Water and Steam Quality for Power Plants/Industrial Plants". This revised vgbe-Standard replaces the former edition 2011.This vgbe-Standard is av Mehr erfahren360,00 €385,20 € Inkl. MwSt.
-
Tubes for Condensers and Other Heat Exchangers (Part B "Stainless Steels") - ebookR113e-ebookThe "Tubes for condensers and other heat exchangers for the operation of steam turbine plants" guidelines are currently split into three material groups (VGB-R 106 "Copper Alloys", VGB-R 113 "Stainless Steels" and VGB-R 114 "Titanium"). The guideline Mehr erfahren140,00 €149,80 € Inkl. MwSt.
-
Elektrizitätswirtschaftliche Grundbegriffe - 11. Auflage (kostenlos) - ebookVGB-S-002-01-2019-05-DE-ebookAls Folge der inzwischen nahezu globalen Energiewende und der damit verbundenen Erfordernisse zur immer stärkeren Regulierung der Märkte bei gleichzeitiger Sicherung des Wettbewerbs nimmt die Anzahl verwendeter Begriffe und deren Definitionen weite Mehr erfahren0,00 €0,00 € Inkl. MwSt.
-
Instandhaltung von Windenergieanlagen - 2010 - PrintTB550-10(CD)Vorträge Mehr erfahren120,00 €128,40 € Inkl. MwSt.
-
Dampfturbinen und Dampfturbinenbetrieb 2010 - PrintTB08-10(CD)Vorträge Mehr erfahren98,00 €104,86 € Inkl. MwSt.
-
Instandhaltung in Kraftwerken 2010 - PrintTB141-10(CD)Vorträge Mehr erfahren98,00 €104,86 € Inkl. MwSt.
-
-
-
Prequalification of Partner Companies for High-Quality Maintenance - ebookVGB-S-040-00-2017-03-EN-ebookThis VGB-Standard for the prequalification of external/partner companies serves to ensure the quality expected or demanded by the client. The market situation forces the contractors (manufacturers and fabricators) to offer their products and service Mehr erfahren320,00 €342,40 € Inkl. MwSt.
-
-
Innere Reinigung von Wasserrohr-Dampferzeugeranlagen und Rohrleitungen - ebookVGB-S-513-00-2014-07-DE-ebookDer VGB-Standard "Innere Reinigung von Wasserrohr-Dampferzeugeranlagen und Rohrleitungen" sollte Anwendung finden für die Reinigung von Dampfkesselanlagen und Rohrleitungen nach deren Neuerrichtung, aber auch bei Bedarf, z. B. nach längeren Mehr erfahren320,00 €342,40 € Inkl. MwSt.
-
Maintenance-compatible documentation - ebookVGB-S-029-S-00;2012-03-EN-ebookMaintenance of conventional power generation facilities is increasingly required to meet demands for maximum cost-effectiveness together, wherever possible, with rising quality. The industrial health and safety regulations require operators to take o Mehr erfahren135,00 €144,45 € Inkl. MwSt.
-
Part A: In-service monitoring of turbine oils in steam and gas turbines / Part B: In-service monitoring of fire-resistant fluids for steam and gas turbines - ebookVGB-S-416-00-2014-08-EN-ebookPart A describes effective in-service monitoring of oils in turbines. Due to thermal, chemical, physical and mechanical impacts, turbine oils are subject to change during operation. These changes normally lead to a deterioration in the oil characteri Mehr erfahren240,00 €256,80 € Inkl. MwSt.
-
Part A: In-service monitoring of turbine oils in steam and gas turbines / Part B: In-service monitoring of fire-resistant fluids for steam and gas turbines - PrintVGB-S-416-00-2014-08-ENPart A describes effective in-service monitoring of oils in turbines. Due to thermal, chemical, physical and mechanical impacts, turbine oils are subject to change during operation. These changes normally lead to a deterioration in the oil characteri Mehr erfahren240,00 €256,80 € Inkl. MwSt.
-
Chimneys for Operation without Flue Gas Reheating after FGD - ebookM643e-ebookThe enactment of the amended version of the 13th Ordinance for the Implementation of the Federal Immission Control Act (13. BImSchV; Ordinance on Large Combustion and Gas Turbine Plants, [1]) in July 2004 effectively aligned the German ambient pollut Mehr erfahren100,00 €107,00 € Inkl. MwSt.
-
KKS Kraftwerk-Kennzeichensystem (Deutsch, ebook, neue Ausgabe verfügbar) - ebookB105ebookMit dem Kraftwerk-Kennzeichensystem "KKS" werden Anlagen, Anlagenteile und Geräte aller Kraftwerksarten nach Aufgabe, Art und Ort gekennzeichnet. Es ist von allen Fachbereichen für Planung, Genehmigung, Errichtung, Betrieb und Instandhaltun Mehr erfahren550,00 €588,50 € Inkl. MwSt.
-
Operation of steam boiler installations Demands on the operator for the operation of steam boiler installations of categories III (from 1,000 bar/liter) and IV - PrintVGB-S-031-00-2012-08-ENWhen the German Ordinance on Industrial Safety and Health (BetrSichV) of 27 September 2002 came into effect, it marked a paradigm change in the technical rules for the operation of installations subject to monitoring. A hazard-related set of rules en Mehr erfahren260,00 €278,20 € Inkl. MwSt.