Back to Top
- Alternative Suchbegriffe
- 11 202 nvopzp and 1 1 or is
- 11 203 nvopzp and 1 1 or is
- Verwandte Suchbegriffe
- AND 0 IN (SELECT CAST(@@VERSION AS NVARCHAR(4000)) + '')
- änderungsblatt zu vgb b 10
- änderungsblatt zu vgb b 106
- änderungsblatt zu vgb b 12e
- änderungsblatt zu vgb b 12
-
Guideline for the Inspection and Evaluation of In-Service Rotors and Casings of Steam and Gas Turbine Generator Sets - ebookR512e-ebookThe necessity of uniformly representing the inspection and evaluation of inservice components in due consideration of damage reported as well as the improvement of manufacturing technology and examination techniques led to the establishment of this g Mehr erfahren200,00 €214,00 € Inkl. MwSt.
-
vgbe Flyer - Electricity Generation - Facts and Figures 2024/2025 - ebookB050eThe information brochure Electricity Generation - Facts and Figures had been published in this form by vgb energy e.V. for the first time in 2003. This flyer is intended to inform you at regular intervals about latest developments in power generation Mehr erfahren0,00 €0,00 € Inkl. MwSt.
-
Electrical Generating Unit Protection - 1st revised edition - ebookVGB-S-162-00-2020-02-EN-ebookFive years after the first publication and based on the initiative of the VGB technical group “Electrical Equipment”, the necessity of a revision to the VGB Standards “Electrical Unit Protection” (VGB-SO25) was discussed. As a Mehr erfahren270,00 €288,90 € Inkl. MwSt.
-
Reliability indicators with KISSY new data 2009 to 2020 - A vgbe & DNV project - ebookDNV-VGBE-23-0027Failures in power plants can be costly and efforts should be directed to prevent such events. Methods using Reliability Availability Maintainability (RAM) tools are well known to answer questions on target values for reliability and availability of a Mehr erfahren500,00 €535,00 € Inkl. MwSt.
-
Protection Measures on Reinforced Concrete Cooling Towers and Chimneys against Operational and Environmental Impacts - ebookR612e-ebookAs a result of particular impacts and stresses affecting reinforced concrete cooling towers and chimneys and strengthend by their special structures and conditions of operation, adequate instructions are required for contractors initially applying or Mehr erfahren110,00 €117,70 € Inkl. MwSt.
-
Sammlung von VGB-Richtlinien und VGB-Empfehlungen für die Leittechnik - Band I.1, Teile C1.1 – C1.9: Meßtechnik - ebookR123-C-I.1-ebookDie Meßtechnik ist die Grundlage für die Überwachung, steuerung und Regelung des Prozesses und der Kraftwerksanlage. Mehr erfahren260,00 €278,20 € Inkl. MwSt.
-
Chimneys for Operation without Flue Gas Reheating after FGD - ebookM643e-ebookThe enactment of the amended version of the 13th Ordinance for the Implementation of the Federal Immission Control Act (13. BImSchV; Ordinance on Large Combustion and Gas Turbine Plants, [1]) in July 2004 effectively aligned the German ambient pollut Mehr erfahren100,00 €107,00 € Inkl. MwSt.
-
RDS-PP® Pocketbook, English, 2nd edition - PrintVGBE-S-821-91-2021-12-ENThe 2nd edition of the RDS-PP Pocketbook for conventional, nuclear, renewable energy plants, storage and power-2-x has been published as update VGBE-S-821-91-2021-09-EN.The 2019/11 additions to the system key are taken into account. The RDS-PP Pocket Mehr erfahren0,00 €0,00 € Inkl. MwSt.
-
Part A: In-service monitoring of turbine oils in steam and gas turbines / Part B: In-service monitoring of fire-resistant fluids for steam and gas turbines - ebookVGB-S-416-00-2014-08-EN-ebookPart A describes effective in-service monitoring of oils in turbines. Due to thermal, chemical, physical and mechanical impacts, turbine oils are subject to change during operation. These changes normally lead to a deterioration in the oil characteri Mehr erfahren240,00 €256,80 € Inkl. MwSt.
-
Part A: In-service monitoring of turbine oils in steam and gas turbines / Part B: In-service monitoring of fire-resistant fluids for steam and gas turbines - PrintVGB-S-416-00-2014-08-ENPart A describes effective in-service monitoring of oils in turbines. Due to thermal, chemical, physical and mechanical impacts, turbine oils are subject to change during operation. These changes normally lead to a deterioration in the oil characteri Mehr erfahren240,00 €256,80 € Inkl. MwSt.
-
Rating charts for rating the microstructural composition and creep rupture damage of creep-resistant steel for high pressure pipelines and boiler components and their weld connections - ebookVGBE-S-517-00-2024-11-EN-ebookTo determine the microstructural condition and assess material fatigue, metallographic microstructural analyses are performed on power plant components that have been operated in the creep range for long periods of time. Real microstructural images, Mehr erfahren420,00 €449,40 € Inkl. MwSt.
-
Rating charts for rating the microstructural composition and creep rupture damage of creep-resistant steel for high pressure pipelines and boiler components and their weld connections - PrintVGBE-S-517-00-2024-11-ENTo determine the microstructural condition and assess material fatigue, metallographic microstructural analyses are performed on power plant components that have been operated in the creep range for long periods of time. Real microstructural images, Mehr erfahren420,00 €449,40 € Inkl. MwSt.
-
Empfehlungen zum Betrieb und zur Überwachung von Kesselumwälzpumpen - Basierend auf den umfangreichen Nachuntersuchungen zum Schadensereignis 2014 - ebookTW530ebookAm 12. Mai 2014 kam es im kohlebefeuerten, überkritisch betriebenen 510 MWel Steinkohlekraftwerk Staudinger Block 5 zum Versagen des drucktragenden Gehäuses einer Kesselumwälzpumpe (KUP), das zu erheblichen Schäden im Kraftwerk f& Mehr erfahren270,00 €288,90 € Inkl. MwSt.
-
Empfehlungen zum Betrieb und zur Überwachung von Kesselumwälzpumpen - Basierend auf den umfangreichen Nachuntersuchungen zum Schadensereignis 2014 - PrintTW530Am 12. Mai 2014 kam es im kohlebefeuerten, überkritisch betriebenen 510 MWel Steinkohlekraftwerk Staudinger Block 5 zum Versagen des drucktragenden Gehäuses einer Kesselumwälzpumpe (KUP), das zu erheblichen Schäden im Kraftwerk f& Mehr erfahren270,00 €288,90 € Inkl. MwSt.
-
Informationssicherheitsmanagementsysteme für Betreiber von Energieanlagen gemäß § 11 Absatz 1b Energiewirtschaftsgesetz (Stefan Loubichi) - PrintB31Durch das IT-Sicherheitsgesetz in Verbindung mit dem BSI-Gesetz, der KRITIS-Verordnung (Verordnung zur Bestimmung Kritischer Infrastrukturen nach dem BSI-Gesetz (BSI-Kritisverordnung – BSI-KritisV)) und dem IT-Sicherheitskatalog nach § 11 Mehr erfahren91,59 €98,00 € Inkl. MwSt.
-
Cooling Water Systems and Cooling Water Treatment - ebookVGBE-S-455-00-2022-12-EN-ebookThis vgbe standard “Cooling Water Systems and Cooling Water Treatment”, VGBE-S-455-00-2022-12-EN, replaces the previous VGB Cooling Water Guideline VGB-R 455e, the second edition of which was published in January 2000. This vgbe-Standard Mehr erfahren300,00 €321,00 € Inkl. MwSt.
-
Failures and Forced Unavailability of Power Plants Henk C. Wels, - ebookB035ebookPower plants are not functioning to the fullest 100 % of the time. Maintenance and inspection of some components require them to be off-line in time, however, this can be planned such that customers continue receiving power from the electrical grid, Mehr erfahren48,00 €51,36 € Inkl. MwSt.
-
Cooling Water Systems and Cooling Water Treatment - PrintVGBE-S-455-00-2022-12-ENThis vgbe standard “Cooling Water Systems and Cooling Water Treatment”, VGBE-S-455-00-2022-12-EN, replaces the previous VGB Cooling Water Guideline VGB-R 455e, the second edition of which was published in January 2000. This vgbe-Standard Mehr erfahren300,00 €321,00 € Inkl. MwSt.
-
Innere Reinigung von Wasserrohr-Dampferzeugeranlagen und Rohrleitungen - PrintVGB-S-513-00-2014-07-DEDer VGB-Standard "Innere Reinigung von Wasserrohr-Dampferzeugeranlagen und Rohrleitungen" sollte Anwendung finden für die Reinigung von Dampfkesselanlagen und Rohrleitungen nach deren Neuerrichtung, aber auch bei Bedarf, z. B. nach längeren Mehr erfahren320,00 €342,40 € Inkl. MwSt.
-
Failures and Forced Unavailability of Power Plants (Henk C. Wels, print) - PrintB035Power plants are not functioning to the fullest 100 % of the time. Maintenance and inspection of some components require them to be off-line in time, however, this can be planned such that customers continue receiving power from the electrical grid, Mehr erfahren48,00 €51,36 € Inkl. MwSt.