Back to Top
- Verwandte Suchbegriffe
- aft nr s 891 00 2014 06 de en
- aft nr s 891 00 201 06 de en
- aft nr s 891 00 221 06 de en
- aft nr s 891 00 210 06 de en
- aft nr s 891 00 2015 06 de en
-
Construction, Operation and Maintenance of Flue Gas Denitrification Systems (DeNOx) - PrintVGB-S-014-2011-ENAfter facilities for reduction of dust emissions were deemed to be state-of-the-art worldwide, beginning in 1970, tests were performed in Germany for the reduction of emissions of SO2 and x. The first measures for the use of combustion technology to Mehr erfahren240,00 €256,80 € Inkl. MwSt.
-
Änderungsblätter zum vgbe/VGB-Regelwerk / Amendments to vgbe/VGB standards kostenlos/free of charge - ebookvgbe-aenderung-fcÄnderungsblätter zum vgbe/VGB-Regelwerk / Amendments to vgbe/VGB standards (kostenlos/free of charge): VGB-B 108 (2014-11) | VGB-S-811 (2019-11 ed. 2022-12) | VGB-S-821 (2019-11 ed. 2022-12) VGB-S-823-31 (2018-10) | VGB-S-832 (2020-05, zur& Mehr erfahren0,00 €0,00 € Inkl. MwSt.
-
Construction, Operation and Maintenance of Flue Gas Denitrification Systems (DeNOx) - ebookVGB-S-014-2011-EN-ebookAfter facilities for reduction of dust emissions were deemed to be state-of-the-art worldwide, beginning in 1970, tests were performed in Germany for the reduction of emissions of SO2 and x. The first measures for the use of combustion technology to Mehr erfahren240,00 €256,80 € Inkl. MwSt.
-
Protection Measures on Reinforced Concrete Cooling Towers and Chimneys against Operational and Environmental Impacts - ebookR612e-ebookAs a result of particular impacts and stresses affecting reinforced concrete cooling towers and chimneys and strengthend by their special structures and conditions of operation, adequate instructions are required for contractors initially applying or Mehr erfahren110,00 €117,70 € Inkl. MwSt.
-
RDS-PP® Pocketbook, English, 2nd edition - PrintVGBE-S-821-91-2021-12-ENThe 2nd edition of the RDS-PP Pocketbook for conventional, nuclear, renewable energy plants, storage and power-2-x has been published as update VGBE-S-821-91-2021-09-EN.The 2019/11 additions to the system key are taken into account. The RDS-PP Pocket Mehr erfahren0,00 €0,00 € Inkl. MwSt.
-
KKS Pocketbook, English, 4th edition - PrintVGBE-S-811-91-2021-12-EN/VGB-B-105-007.4eThe 4th edition of the KKS Pocketbook (KKS - Kraftwerk-Kennzeichensystem/Identification System for Power Stations) for conventional, nuclear, renewable energy plants, storage and power-2-x has been published as update VGBE-S-811-91-2021-09-EN.The 201 Mehr erfahren0,00 €0,00 € Inkl. MwSt.
-
Monitoring, limiting and protection devices on steam turbine plants - PrintVGB-S-103-00-2020-02-ENThis standard is addressed to manufacturers, service providers and operators of steam turbine plants and is in particular to assist operators in equipping their steam turbine plants. The safe operation of steam turbines makes great demands on Mehr erfahren270,00 €288,90 € Inkl. MwSt.
-
Monitoring, limiting and protection devices on steam turbine plants - ebookVGB-S-103-00-2020-02-EN-ebookThis standard is addressed to manufacturers, service providers and operators of steam turbine plants and is in particular to assist operators in equipping their steam turbine plants. The safe operation of steam turbines makes great demands on Mehr erfahren270,00 €288,90 € Inkl. MwSt.
-
Richtreihen zur Bewertung der Gefügeausbildung und Zeitstandschädigung warmfester Stähle für Hochdruckrohrleitungen und Kesselbauteile und deren Schweißverbindungen - ebookVGBE-S-517-00-2024-11-DE-ebookZur Ermittlung des Gefügezustandes und Feststellung der Werkstofferschöpfung werden an langzeitig im Kriechbereich betriebenen Kraftwerkskomponenten bauteilmetallografische Gefügeuntersuchungen durchgeführt. Reale Gefügebilder, Teil dieses vgbe- Mehr erfahren420,00 €449,40 € Inkl. MwSt.
-
Richtreihen zur Bewertung der Gefügeausbildung und Zeitstandschädigung warmfester Stähle für Hochdruckrohrleitungen und Kesselbauteile und deren Schweißverbindungen - PrintVGBE-S-517-00-2024-11-DEZur Ermittlung des Gefügezustandes und Feststellung der Werkstofferschöpfung werden an langzeitig im Kriechbereich betriebenen Kraftwerkskomponenten bauteilmetallografische Gefügeuntersuchungen durchgeführt. Reale Gefügebilder, Teil dieses vgbe- Mehr erfahren420,00 €449,40 € Inkl. MwSt.
-
Operation of steam boiler installations Demands on the operator for the operation of steam boiler installations of categories III (from 1,000 bar/liter) and IV - PrintVGB-S-031-00-2012-08-ENWhen the German Ordinance on Industrial Safety and Health (BetrSichV) of 27 September 2002 came into effect, it marked a paradigm change in the technical rules for the operation of installations subject to monitoring. A hazard-related set of rules en Mehr erfahren260,00 €278,20 € Inkl. MwSt.
-
Operation of steam boiler installations Demands on the operator for the operation of steam boiler installations of categories III (from 1,000 bar/liter) and IV - ebookVGB-S-031-00-2012-08-EN-ebookWhen the German Ordinance on Industrial Safety and Health (BetrSichV) of 27 September 2002 came into effect, it marked a paradigm change in the technical rules for the operation of installations subject to monitoring. A hazard-related set of rules en Mehr erfahren260,00 €278,20 € Inkl. MwSt.
-
Rating charts for rating the microstructural composition and creep rupture damage of creep-resistant steel for high pressure pipelines and boiler components and their weld connections - ebookVGBE-S-517-00-2024-11-EN-ebookTo determine the microstructural condition and assess material fatigue, metallographic microstructural analyses are performed on power plant components that have been operated in the creep range for long periods of time. Real microstructural images, Mehr erfahren420,00 €449,40 € Inkl. MwSt.
-
Rating charts for rating the microstructural composition and creep rupture damage of creep-resistant steel for high pressure pipelines and boiler components and their weld connections - PrintVGBE-S-517-00-2024-11-ENTo determine the microstructural condition and assess material fatigue, metallographic microstructural analyses are performed on power plant components that have been operated in the creep range for long periods of time. Real microstructural images, Mehr erfahren420,00 €449,40 € Inkl. MwSt.
-
Empfehlungen für den maschinentechnischen Generatorschutz - ebookVGB-S-164-11-2016-08-DE-ebookUm Schäden an Generatoren in Kraftwerken bereits im Entstehungsstadium zu erfassen, werden Schutzeinrichtungen eingebaut. Der VGB-Standard S-164-11 zeigt die Schutzmaßnahmen auf, die sich aus der Überschreitung thermischer Grenzen, de Mehr erfahren280,00 €299,60 € Inkl. MwSt.
-
Recommendations for thermal/mechanical generator protection - PrintVGB-S-164-11-2016-08-ENTo detect incipient damage to generators in power plants, protective equipment is installed. For electrical protection, in 2012 VGB published recommendations in the VGB-Standard VGB-S-025 “Electrical Generating Unit Protection”. The VGBSt Mehr erfahren280,00 €299,60 € Inkl. MwSt.
-
Recommendations for thermal/mechanical generator protection - ebookVGB-S-164-11-2016-08-EN-ebookTo detect incipient damage to generators in power plants, protective equipment is installed. For electrical protection, in 2012 VGB published recommendations in the VGB-Standard VGB-S-025 “Electrical Generating Unit Protection”. The VGBSt Mehr erfahren280,00 €299,60 € Inkl. MwSt.
-
BTR - Bautechnik bei Kühltürmen - PrintVGB-S-610-00-2019-10-DEDer vorliegende VGB-Standard stellt – gemeinsam mit der VGB-R 135 und der VGB-R 612 – eine vereinheitlichende Grundlage für die bautechnische Entwurfs-, Genehmigungs- und Ausführungsplanung sowie für die Bauausführung Mehr erfahren270,00 €288,90 € Inkl. MwSt.
-
BTR - Bautechnik bei Kühltürmen - ebookVGB-S-610-00-2019-10-DE-ebookDer vorliegende VGB-Standard stellt – gemeinsam mit der VGB-R 135 und der VGB-R 612 – eine vereinheitlichende Grundlage für die bautechnische Entwurfs-, Genehmigungs- und Ausführungsplanung sowie für die Bauausführung Mehr erfahren270,00 €288,90 € Inkl. MwSt.
-
Rohre für Kondensatoren und andere Wärmeaustauscher - Kupferlegierungen - ebookR106ebookDie VGB-Richtlinien „Rohre für Kondensatoren und andere Wärmeaustauscher“ sind derzeit in drei Werkstoffgruppen (R 106 „Kupferlegierungen“, R 113 „Nichtrostende Stähle“ und R 114 „Titan“) Mehr erfahren140,00 €149,80 € Inkl. MwSt.