Application, design and quality assurance criteria for the use of fibre-reinforced plastics in power plant construction - PrintVGB-S-609-00-2016-03-ENThis VGB-Standard replaces the former VGB guideline VGB-R 609e, which had the same title and dates from 2003. Mehr erfahren220,00 €235,40 € Inkl. MwSt.
-
Maßnahmen an Kühltürmen und Schornsteinen aus Stahlbeton zum Schutz gegen Betriebs- und Umgebungseinwirkungen - ebookR612ebookAufgrund spezieller Einwirkungen und Beanspruchungen sowie außergewöhnlicher Bauwerksstrukturen und Nutzungsbedingungen bei Kühltürmen und bei Schornsteinen aus Stahlbeton sind zur Erstausführung oder Erneuerung von Oberfl&a Mehr erfahren110,00 €117,70 € Inkl. MwSt.
-
Application, design and quality assurance criteria for the use of fibre-reinforced plastics in power plant construction - ebookVGB-S-609-00-2016-03-EN-ebookThis VGB-Standard replaces the former VGB guideline VGB-R 609e, which had the same title and dates from 2003. Mehr erfahren220,00 €235,40 € Inkl. MwSt.
-
Sampling and Physico-Chemical Monitoring of Water and Steam Cycles - PrintVGB-S-006-00-2012-09-ENThis Standard VGB-S-006-00-2012-09-EN is intended to supplement VGB-S-010-T-00;2011-12.EN Standard for Feed Water, Boiler Water and Steam Quality for Power Plants / Industrial Plants (formerly VGB Standard VGB-R-450-Le) and to give recommendations fo Mehr erfahren190,00 €203,30 € Inkl. MwSt.
-
Sampling and Physico-Chemical Monitoring of Water and Steam Cycles - ebookVGB-S-006-00-2012-09-EN-ebookThis Standard VGB-S-006-00-2012-09-EN is intended to supplement VGB-S-010-T-00;2011-12.EN Standard for Feed Water, Boiler Water and Steam Quality for Power Plants / Industrial Plants (formerly VGB Standard VGB-R-450-Le) and to give recommendations fo Mehr erfahren190,00 €203,30 € Inkl. MwSt.
-
Monitoring, limiting and protection devices on steam turbine plants - PrintVGB-S-103-00-2020-02-ENThis standard is addressed to manufacturers, service providers and operators of steam turbine plants and is in particular to assist operators in equipping their steam turbine plants. The safe operation of steam turbines makes great demands on Mehr erfahren270,00 €288,90 € Inkl. MwSt.
-
Einsatzmöglichkeiten von Kunststoffen in Kühltürmen - ebookM621ebookDas vorliegende Merkblatt ist eine Sammlung von Erfahrungen und Erkenntnissen, die den Stand der Technik beim Einsatz von Kunststoffbauteilen - soweit diese nicht der Prüfpflicht im Sinne der Bauordnungen unterliegen - in Kühltürmen da Mehr erfahren140,00 €149,80 € Inkl. MwSt.
-
Monitoring, limiting and protection devices on steam turbine plants - ebookVGB-S-103-00-2020-02-EN-ebookThis standard is addressed to manufacturers, service providers and operators of steam turbine plants and is in particular to assist operators in equipping their steam turbine plants. The safe operation of steam turbines makes great demands on Mehr erfahren270,00 €288,90 € Inkl. MwSt.
-
Nahstöchiometrischer Betrieb von Ölfeuerungen - ebookM204ebookDer nahstöchiometrische Betrieb von Ölfeuerungen gehört heute zum Stand der Technik. Es bestehen gegenwärtig keine grundsätzlichen technischen Schwierigkeiten mehr, einen solchen Betrieb durchzuführen. Der bei Kesselanla Mehr erfahren30,00 €32,10 € Inkl. MwSt.
-
Sampling Points for Process Measurements in Water and Steam Carrying Systems – Type, Selection and Design - PrintVGB-S-170-42-2014-08-ENThe VGB-Standard VGB-S-170-42-2014-08-EN was prepared for the purpose of standardizing the design of sampling points for process measurements in water and steam carrying systems, as well as for specifying the requirements and facilitating the replace Mehr erfahren140,00 €149,80 € Inkl. MwSt.
-
Quality requirements for mineral oils in power transformers - PrintVGB-S-169-11-2015-11-ENThe objective of the VGB-Standard is to safeguard the required quality criteria for the complete production processes up to and including commissioning and first start-up. It is intended as a pragmatic aid for the users. Mehr erfahren200,00 €214,00 € Inkl. MwSt.
-
Quality requirements for mineral oils in power transformers - ebookVGB-S-169-11-2015-11-EN-ebookThe objective of the VGB-Standard is to safeguard the required quality criteria for the complete production processes up to and including commissioning and first start-up. It is intended as a pragmatic aid for the users. Mehr erfahren200,00 €214,00 € Inkl. MwSt.
-
Measures for the avoidance and handling of instrumentation and control equipment failures - ebookVGB-S-170-12-2018-08-EN-ebookThe former VGB Guideline VGB-R 170 A1e “Measures for the avoidance and handling of instrumentation and control equipment failures” was used since 2005 for the support during the specification and assessment of control and instrumentation Mehr erfahren140,00 €149,80 € Inkl. MwSt.
-
Bauart, Betrieb und Wartung von Rauchgasentstickungsanlagen (DeNOx) - PrintVGB-S-014-2011-DEDer VGB-Standard spannt einen Bogen von den Anfängen dieser Technologie in Japan bis hin zum heutigen Betrieb mit den entsprechenden prozesstechnischen Regelsystemen und der Instandhaltung. Auch Entwicklungen in der Entstickungstechnologie, die Mehr erfahren240,00 €256,80 € Inkl. MwSt.
-
Bauart, Betrieb und Wartung von Rauchgasentstickungsanlagen (DeNOx) - ebookVGB-S-014-2011-DE-ebookDer VGB-Standard spannt einen Bogen von den Anfängen dieser Technologie in Japan bis hin zum heutigen Betrieb mit den entsprechenden prozesstechnischen Regelsystemen und der Instandhaltung. Auch Entwicklungen in der Entstickungstechnologie, die Mehr erfahren240,00 €256,80 € Inkl. MwSt.
-
Kraftwerksbekohlung - ebookM211ebookSeit der ersten Auflage des VGB-Merkblattes „Kraftwerksbekohlung“ im Jahre 1980 hat sich der Steinkohleanteil zur Stromerzeugung in Deutschland überwiegend von heimi-scher auf Importkohle verlagert. Gegenüber dem annähernd Mehr erfahren100,00 €107,00 € Inkl. MwSt.
-
Avoidance of generator damage resulting from condensation on live parts - PrintVGB-S-164-12-2016-10-ENThe moisture contained in gaseous substances condenses on impact with colder surfaces to a greater of lesser extent, depending on the ambient conditions and in particular on pressure and temperature. If this occurs in the area of non-insulated electr Mehr erfahren280,00 €299,60 € Inkl. MwSt.
-
Avoidance of generator damage resulting from condensation on live parts - ebookVGB-S-164-12-2016-10-EN-ebookThe moisture contained in gaseous substances condenses on impact with colder surfaces to a greater of lesser extent, depending on the ambient conditions and in particular on pressure and temperature. If this occurs in the area of non-insulated electr Mehr erfahren280,00 €299,60 € Inkl. MwSt.
-
Lernzielkontrollen in der Aus- und Weiterbildung von Kernkraftwerkspersonal - PrintVGB-S-028-00-2012-03-DELernzielkontrollen sollen grundsätzlich fester Bestandteil jeder Schulungsmaßnahme sein. Deshalb richtet sich dieser VGB-Standard an die Ausbilder/Referenten, die Lernenden und das für die Schulungsmaßnahme verantwortliche Personal. Bei der Erst Mehr erfahren65,00 €69,55 € Inkl. MwSt.
-
Maßnahmen zur Vermeidung und Beherrschung von Leittechnikausfällen - PrintVGB-S-170-12-2018-08-DEDie ehemalige VGB Richtlinie VGB-R 170 A1 „Maßnahmen zur Vermeidung und Beherrschung von Leittechnikausfällen“ wurde seit 2005 als Unterstützung bei der Spezifikation nd Bewertung von leittechnischen Systemen hinsichtlich Mehr erfahren140,00 €149,80 € Inkl. MwSt.